Filtrovat podle
Nalezen výsledek pro CMM
Testing and verification
Testing and verification The machine manufacturer or the installer of the UCC S5 is responsible for ensuring that the following testing and verification is performed to the appropriate standard:...
Testing and verification
Testing and verification NOTE: It is strongly recommended that any measuring equipment is regularly checked for accuracy.
MCUlite-2
MCUlite-2 Technical specification MCU comparison ■ Standard specification - Not available MCUlite-2 MCU5 MCU W MCU5-2 MCU W-2 Display window - ■ ■ ■ ■ Fast / slow button ■ On paddle On paddle On...
PHS-2 introduction
PHS-2 introduction The Renishaw servo positioning head (PHS-2) is a two axis motorised head with ±184° servo drive enabling the probe configuration to be positioned at almost any angle.
UCC AI introduction
UCC AI introduction Key Description Key Description 1 Scale 0 interface (15W HDD socket) 7 PICS (9W D socket) 2 Scale 1 interface (15W HDD socket) 8 UCC - SPA (RJ45 socket) 3 Scale 2 interface...
SFP2 probe for REVO at EMO 2017
Video presenting the advantages of the new SFP2 surface finish measurement probe for the REVO system, which delivers dimensional and roughness finish measurement from a single CMM.
Ethernet cable link to PC
Ethernet cable link to PC This is a standard ethernet CAT 5E cable, a 5 m cable is supplied as part of the CMM controller kit. Lengths up to 100 metres can be used.
Ethernet cable link to PC
Ethernet cable link to PC This is a standard ethernet CAT 5E cable, a 5 m cable is supplied as part of the CMM controller kit. Lengths up to 100 metres can be used.
PL1, PL2 and PL3 manual probe head cables
These coiled cables have an in-line 5-pin DIN plug at end 'A' and a 90° moulded plastic 5-pin DIN plug at end 'B'. They electrically connect Renishaw manual probe heads to the CMM quill.
R-CTT-40-30-6 - 36.2 mm soft tip tension clamp with 30.0 mm post and M6 thread
This tension clamp has a rubber-coated tip to hold workpieces without scratching or marking the workpiece surfaces.
R-AVP-2525-6 - Ø25.1 mm × 25.0 mm adjustable V post with M6 thread
This adjustable V post is used to hold cylindrical or tubular parts without marking their surfaces.
Head alignment for ACR3
Head alignment for ACR3 Alignment of the head - pitch The pitch axis of the head is from the front of the probe head (where the LED is located) to the rear of the probe head.
TP200 product description
TP200 product description NOTE: Renishaw does not recommend the use of TP200B with the LF module or cranked / star styli.
A-1371-1100 - MCR20 rack kit for automatic stylus changing with TP20 - low force module
The MCR20 module changing rack is designed to securely store up to six TP20 probe modules for automatic changing, and to protect them from airborne contaminants.
A-3060-0086 - REVO® tip datum artefact (TDA) - bed-mounted
Probe and stylus changes may lead to fractional variations in the alignment of a CMM system when compared with the original calibration.
A-1371-0261 - MCR20 rack kit for automatic stylus changing with TP20 - standard force module
The MCR20 module changing rack is designed to securely store up to six TP20 probe modules for automatic changing, and to protect them from airborne contaminants.
A-1371-0266 - MCR20 rack kit for automatic stylus changing with TP20 - extended force module
The MCR20 module changing rack is designed to securely store up to six TP20 probe modules for automatic changing, and to protect them from airborne contaminants.
A-1371-0264 - MCR20 rack kit for automatic stylus changing with TP20 - medium force module
The MCR20 module changing rack is designed to securely store up to six TP20 probe modules for automatic changing, and to protect them from airborne contaminants.
R-CT-100P-83-8 - 92.0 mm tension clamp with 82.8 mm post and adjustable plunger tip and M8 thread
This tension clamp is used for the quick and easy clamping of workpieces onto CMM and Equator™ systems.
REVO calibration
REVO calibration The REVO datum sphere is used to calibrate the REVO head as well as RSP2 V2 and RSP3-# probe configurations.
MH20 and MH20i installation
MH20 and MH20i installation Mounting the shank to the probe head The MH20 and MH20i shanks are factory fitted and are selected by part no.
MCUlite-2, MCU5-2 and MCU W-2 installation and user's guide
MCUlite-2, MCU5-2 and MCU W-2 installation and user's guide NOTE: Please use the left-hand navigation to view this complete document.
Measurement configuration parameters
Measurement configuration parameters See also: MCG tools setup worksheet CMM setup parameters Measuring condition parameters MCG part program generation Languages supported by MCG On the set up ...
Using the SP600, SP600M and SP600Q
Using the SP600, SP600M and SP600Q Reorientation The SP600M probe may be used in different orientations when mounted on a Renishaw PH10M PLUS motorised head.
RTP20 user's guide
RTP20 is an indexable head that uses the CMM's motion for repeatable repositioning. It offers low-cost ‘motorised' head functionality with an integral TP20 touch-trigger probe.
UCC T5 introduction
UCC T5 introduction The UCC T5 is the latest generation Renishaw CMM controller product.
3-axis vs 5-axis co-ordinate measuring machine technology
An introduction to some of the fundamental basics of co-ordinate measuring machine (CMM) technology.
TP200 fault finding
TP200 fault finding False (‘air') triggers occur while the CMM is stationary and the probe LEDs flicker: PI 200-3 indicators Possible causes Remedy 'STD' LED ON 'SEATED' LED OFF Probe...
Probe inertia
Probe inertia Due to the inertia of the SP80 / SP80H motion system high CMM accelerations may cause non-contact probe deflections to exceed thresholds set within the control algorithms this inertia...
Renconnect
Renconnect Renconnect is a powerful support tool that provides a link between you and the resources of the Renishaw CMM support team.
A-1371-0267 - MCR20 rack kit for automatic stylus changing with TP20 - standard and low force modules
The MCR20 module changing rack is designed to securely store up to six TP20 probe modules for automatic changing, and to protect them from airborne contaminants.
A-1371-0268 - MCR20 rack kit for automatic stylus changing with TP20 - medium and low force modules
The MCR20 module changing rack is designed to securely store up to six TP20 probe modules for automatic changing, and to protect them from airborne contaminants.
A-1371-0262 - MCR20 rack kit for automatic stylus changing with TP20 - standard and medium force modules
The MCR20 module changing rack is designed to securely store up to six TP20 probe modules for automatic changing, and to protect them from airborne contaminants.
A-1371-0263 - MCR20 rack kit for automatic stylus changing with TP20 - standard and extended force modules
The MCR20 module changing rack is designed to securely store up to six TP20 probe modules for automatic changing, and to protect them from airborne contaminants.
A-1371-0265 - MCR20 rack kit for automatic stylus changing with TP20 - medium and extended force modules
The MCR20 module changing rack is designed to securely store up to six TP20 probe modules for automatic changing, and to protect them from airborne contaminants.
Using HCU1
Using HCU1 Layout Key 1.
CMM Stylus Selection
Image of styli for CMM selection
CMM inspection fundamentals
The factors that affect CMM measurement performance and your choice of probing solution.
CMM-technical-specification
CMM-technical-specification
CMM shuttle system
Image of a CMM shuttle system
CMM fixture banner
CMM fixture banner for web
CMM Technology Guide
Download CMM technology guide
CMM Technology Guide
Download CMM technology guide
CMM shuttle system
This shuttle system is ideal for moving parts on and off a CMM or moving fixtures/parts in and out of an enclosed CMM.
Custom CMM fixture
This image shows a custom fixture for a CMM, designed to inspect pill dyes.
CMM Demo area
new mills,demonstration,cmm
CMM plate clamp
Non-marking clamp for securing 13 mm and 19 mm thick plates to a CMM. Includes screws for M8, M10 and M12 inserts.
CMM retrofits button
CMM retrofits
CMM fixturing plates
Stack of CMM plates.
CMM Demo area