Filtrovat podle
Nalezen výsledek pro CMM

Ethernet cable link to PC
Ethernet cable link to PC This is a standard ethernet CAT 5E cable, a 5 m cable is supplied as part of the CMM controller kit. Lengths up to 100 metres can be used.

Installing a manual probe head
Installing a manual probe head Fitting an M8-threaded CMM touch-trigger probe to a manual probe head Fit an M8-threaded non-autojointed CMM touch-trigger probe to a manual probe head as...

PHC10-3 PLUS troubleshooting
PHC10-3 PLUS troubleshooting Power on LED not lit Possible cause Solution Power loss Check mains cable connections and integrity.

R-CT-4P-325-20 - Tension clamp plunger with 3.26 in post and 1/4-20 thread

This tension clamp is used for the quick and easy clamping of workpieces onto CMM and Equator™ systems.

R-T-35450-8 - 35 mm × 35 mm × 450 mm tower (2 sides, 2 rows, 2 sides, 1 row) with M8 thread

This tower is used to fixture large workpieces or to hold a workpiece vertically. It has M8 threaded holes spaced at 12.5 mm intervals and is recommended for use on CMM and Equator™ gauging systems.

PL4 manual probe head cable
This straight cable has an in-line 5-pin DIN plug at end 'A' and a 90° moulded plastic 5-pin DIN plug at end 'B'. It electrically connects Renishaw manual probe heads to the CMM quill.

SFP2 surface finish probe for the REVO® system
The REVO SFP2 sensor enables automated inspection of surface finish, fully integrated with part geometry measurement.

Overview of the REVO® 5-axis multi-sensor system's technical features
Unlike conventional CMM systems, the REVO system uses synchronised motion and 5-axis measurement technology to minimise the dynamic effects of coordinate measurement machine (CMM) motion at...

RS232 setup
RS232 setup RS232 connector pinouts The PHC10-3 PLUS communicates with the CMM computer via the RS232 cable as shown in the table below: Pin Signal 1 Screen 2 Transmitted data (Tx) to CMM...

PH10 PLUS troubleshooting
PH10 PLUS troubleshooting Overload error Possible cause Solution Head lock up holding force exceeded during CMM acceleration Reduce mass of probe combination.

PH10M-iQ PLUS troubleshooting
PH10M-iQ PLUS troubleshooting Overload error Possible cause Solution Head lock up holding force exceeded during CMM acceleration Reduce mass of probe combination.

REVO system
The REVO® 5-axis multi-sensor system delivers high performance scanning, non-contact inspection and surface finish analysis on a single CMM.

Head axis range
Head axis range * This movement is for calibration and use of RSP3 probes only.

Retrofit cabinet - legacy
Renishaw's controller cabinet is a standard 19 inch rack mounting unit that is used for storing Renishaw's range of controllers, servo power amplifiers and interfaces

TP20 warnings
TP20 warnings The use of eye protection is recommended.

USB communications
USB communications USB communication is via the USB type "B" socket on the rear panel.

CAD compatibility
CAD compatibility MODUS accesses geometry data directly from the native CAD model, ensuring there is no loss of accuracy when using CAD data for inspection programming.

Renishaw: enhancing efficiency in manufacturing and healthcare
In metrology, motion control, machine calibration, dental CAD/CAM, additive manufacturing, spectroscopy and neurosurgery, Renishaw innovations enhance precision, efficiency and quality.

REVO-2 references and associated documents
REVO-2 references and associated documents The following Renishaw documents are referred to in this document or may be a source of further relevant information.

Probe inertia
Probe inertia Due to the inertia of the SP80 / SP80H motion system high CMM accelerations may cause non-contact probe deflections to exceed thresholds set within the control algorithms this inertia...

Renconnect
Renconnect Sorry, you do not currently have access to this page.

PL17 and PL18 manual probe head cables
These coiled cables have a 90° moulded 5-pin DIN plug at end 'A' and an in-line LEMO plug at end 'B'. They electrically connect Renishaw manual probe heads to the CMM quill.

PL31 manual probe head cable
These coiled cables have a 90° moulded 5-pin DIN plug at end 'A' and an in-line LEMO plug at end 'B'. They electrically connect Renishaw manual probe heads to the CMM quill.

A-3060-0086 - REVO® tip datum artefact (TDA) - bed-mounted

Probe and stylus changes may lead to fractional variations in the alignment of a CMM system when compared with the original calibration.

R-CT-100P-83-8 - 92.0 mm tension clamp with 82.8 mm post and adjustable plunger tip and M8 thread

This tension clamp is used for the quick and easy clamping of workpieces onto CMM and Equator™ systems.

Gear inspection is 30 times faster with form measurement
Meltham Mills Engineering (MME) now takes only eight minutes to inspect every critical feature on a typical gear component, compared to four hours previously – 30 times faster.

3-axis vs 5-axis co-ordinate measuring machine technology
An introduction to some of the fundamental basics of co-ordinate measuring machine (CMM) technology.

General wiring standards for the installation of the SPA3-2
General wiring standards for the installation of the SPA3-2 CAUTION: Motor cables must have a minimum cross section of 0.

General wiring standards for the installation of the SPA3
General wiring standards for the installation of the SPA3 To achieve reliable operation of the SPA3 plus UCC, the following should be observed: The PSU must be single fault tolerant, approved to...

Strain-gauge machine-tool probe is right for 5-axis aerospace parts
Flat surfaces and straight lines are rare among the parts produced at Triumph Fabrications in Shelbyville, Indiana, which is a key reason the company upgraded the machine tool probe on one of its...

Datuming MCR20
Datuming MCR20 NOTES: Renishaw recommends that datuming of the MCR20 is performed using the Renishaw PS2R stylus supplied.

PL5, PL6 and PL13 motorised probe head cables
These coiled cables have an in-line LEMO plug at end 'A' and a 90° Tuchel socket at end 'B'. They electrically connect Renishaw PH10T, PH10M or PH10MQ motorised probe heads to the CMM quill.

PL14 manual probe head cable
This coiled cable has a 7-pin Amphenol plug at end 'A' and a 90° moulded plastic 5-pin DIN plug at end 'B'. It electrically connects Renishaw manual probe heads to the CMM quill.

PL12 motorised probe head cable
This straight cable has an in-line LEMO plug at end 'A' and a 90° Tuchel socket at end 'B'. It electrically connects Renishaw PH10T, PH10M or PH10MQ motorised probe heads to the CMM quill.

UCC T3-2 introduction
UCC T3-2 introduction The UCC T3-2 is the latest generation Renishaw CMM controller product range.

Temperature compensation
Temperature compensation System accuracy and calibration The TEC system can be used without calibration.

Temperature compensation
Temperature compensation System accuracy and calibration The TEC system can be used without calibration.

Temperature compensation
Temperature compensation NOTE: Thermal compensation is activated and setup through UCCassist-2.

Probe specification
Probe specification RSP2 V2 RSP3-# SFP1 Used for High-speed 5-axis 2D scanning * with single point taking.

UCC BI introduction
UCC BI introduction NOTE: Please see 'Troubleshooting' section for assistance in diagnosing system faults.

MCU W legacy hand controller
Based on the MCU5 joystick design, the MCU W uses lithium ion battery technology and wireless Bluetooth® connectivity

MCU5-2
MCU5-2 Retrofits Learn about retrofitting options for your CMM.

SFP2 probe for REVO at EMO 2017
Video presenting the advantages of the new SFP2 surface finish measurement probe for the REVO system, which delivers dimensional and roughness finish measurement from a single CMM.

DMIS part program generation parameters
DMIS part program generation parameters The user can choose both the north and south latitudes.

UCC DMT maintenance
UCC DMT maintenance Check the security of mounting screws and USB connector Remove dust from the external surfaces with a proprietary cleaning cloth There are no user servicable parts within the UC...

UCC AI installation
UCC AI installation Width Depth Height Weight 440 mm (17.

New QuickLoad™ rail system improves speed, throughput and accuracy during part inspection
Renishaw is pleased to announce the introduction of the QuickLoad™ rail system to its range of metrology fixturing.

CMM inspection of a hairpin stator using the REVO® multi-sensor system
Fast and automated CMM inspection of a hairpin stator using the REVO® multi-sensor system.

PL93 motorised probe head cable
This straight cable has an in-line LEMO plug at end 'A' and an in-line Tuchel socket at end 'B'. It electrically connects Renishaw PH10T, PH10M or PH10MQ motorised probe heads to the CMM quill.

Taking measurements with MCG
Taking measurements with MCG Taking measurements when using MCG Tools Renishaw have simplified the implementation of using an MCG by providing on-line MCG Tools on the Renishaw website: www.