Nalezen výsledek pro CMM

Measuring condition parameters

Measuring condition parameters

Measuring condition parameters Temperature This field holds a temperature recorded during the MCG test This is a manual entry This field is archived Atmospheric pressure This field holds the atm...

System overview

System overview

System overview UCC T3 is an addition to the Renishaw CMM controller product range.

MRS system description

MRS system description

MRS system description MRS heavy duty legs Where heavier rack systems or longer styli configurations are used, such as multiple SCP80s or RCP TC-2 / RCP TC-3s, the MRS system can be upgraded by...

UCC T5 introduction

UCC T5 introduction

UCC T5 introduction The UCC T5 is the latest generation Renishaw CMM controller product.

PHS-2 introduction

PHS-2 introduction

PHS-2 introduction The Renishaw servo positioning head (PHS-2) is a two­ axis motorised head with ±184° servo drive enabling the probe configuration to be positioned at almost any angle.

UCC AI introduction

UCC AI introduction

UCC AI introduction NOTE: Please see 'Troubleshooting' section for assistance in diagnosing system faults.

MCUlite-2

MCUlite-2

MCUlite-2 Retrofits Learn about retrofitting options for your CMM.

TP200 product description

TP200 product description

TP200 product description Probe body The TP200 probe body houses the strain sensing structure and electronic processing circuitry.

Head alignment for ACR3

Head alignment for ACR3

Head alignment for ACR3 In the majority of installations only the yaw of the motorised head requires alignment.

UDS universal datum sphere

UDS universal datum sphere

Regular requalification of your probe using Renishaw's universal datum sphere enhances the performance of your manual or fully automated CMM.

A-5764-0010 - SFP2 surface finish probe with C-axis

A-5764-0010 - SFP2 surface finish probe with C-axis

A-5764-0010 - SFP2 surface finish probe with C-axis

The SFP2 probe increases the surface finish measurement ability of the REVO® system, which offers multi‑sensor capability providing touch-trigger, high speed tactile scanning and non‑contact vision...

R-QLPC-5066-50-20 - 1/4-20 QuickLoad™ plate, 0.50 in × 6.00 in × 6.00 in

R-QLPC-5066-50-20 - 1/4-20 QuickLoad™ plate, 0.50 in × 6.00 in × 6.00 in

R-QLPC-5066-50-20 - 1/4-20 QuickLoad™ plate, 0.50 in × 6.00 in × 6.00 in

This CMM precision ground, aluminium QuickLoad™ base plates have multiple 1/4-20 threaded holes spaced at 0.5 '' intervals to increase the flexibility of your fixture.

Using the SP600, SP600M and SP600Q

Using the SP600, SP600M and SP600Q

Using the SP600, SP600M and SP600Q Qualification The SP600M family of probes require qualification before they are able to give accurate positional data.

MCU5

MCU5

MCU5 Retrofits Learn about retrofitting options for your CMM.

PL15 manual probe head cable

PL15 manual probe head cable

This straight cable has an in-line 5-pin DIN plug at end 'A' and is unterminated at end 'B'. It electrically connects Renishaw manual probe heads to the CMM quill.

Software

Software

Software

Gauging and inspection software training

Gauging and inspection software training

Gauging and inspection software training Renishaw offers standard and specialised MODUS™ metrology software training courses to meet your requirements.

TP20 modules

TP20 modules

Modules offering a range of trigger forces allow the probe performance to be best matched to the measurement task.

PL172 PHC10-3 three-way linking cable

PL172 PHC10-3 three-way linking cable

This cable is used to combine a multiwire system with a standard touch-trigger probe system using the PHC10-3 7-pin DIN raw probe input connector, without the need for an IS1-2 interface selector to...

R-CTB-1-20 - 1/4-20 tension clamp bracket

R-CTB-1-20 - 1/4-20 tension clamp bracket

R-CTB-1-20 - 1/4-20 tension clamp bracket

This tension clamp bracket attaches to a standoff and holds the tension clamp at an angle.

R-CTB-75-20 - 1/4-20 tension clamp bracket

R-CTB-75-20 - 1/4-20 tension clamp bracket

R-CTB-75-20 - 1/4-20 tension clamp bracket

This tension clamp bracket attaches to a standoff and holds the tension clamp at an angle.

MH20 and MH20i installation

MH20 and MH20i installation

MH20 and MH20i installation Mounting the shank to the probe head The MH20 and MH20i shanks are factory fitted and are selected by part no.

Measurement configuration parameters

Measurement configuration parameters

Measurement configuration parameters On the set up worksheet, the user identifies the machine checking gauge with the following fields: MCG identification This field holds the serial number of th...

REVO calibration

REVO calibration

REVO calibration The REVO datum sphere is used to calibrate the REVO head as well as RSP2 V2 and RSP3-# probe configurations.

Using HCU1

Using HCU1

Using HCU1 Layout Key 1.

Racks and ports - AU declarations of conformity

Racks and ports - AU declarations of conformity

Racks and ports - AU declarations of conformity Browse documents racks ACR1 with powered port AUD2023-01147-01-A

Controllers

Controllers

Controllers Contents Interfaces and controllers PI4 PI7-2 PI200 IS1-2 PHC10-2 UCClite-2 UCCFusion UCC2 Hand controllers ACC2-2 SPAlite SPA2-2 UCC2 universal CMM controlle...

UCC2 legacy controller

UCC2 legacy controller

UCC2 legacy controller Renishaw's universal CMM controller is suitable for touch-trigger and scanning probing UCC2 is the controller platform for the revolutionary 5-axis scanning technology.

Built on standards

Built on standards

MODUS is built on industry standards such as the I++ DME protocol, native DMIS and a Microsoft SQL Server database.

PL4 manual probe head cable

PL4 manual probe head cable

This straight cable has an in-line 5-pin DIN plug at end 'A' and a 90° moulded plastic 5-pin DIN plug at end 'B'. It electrically connects Renishaw manual probe heads to the CMM quill.

R-T-1512-20 - 2.00 in × 1.50 in × 12.00 in tower (4 sides, 2 rows) with 1/4-20 thread

R-T-1512-20 - 2.00 in × 1.50 in × 12.00 in tower (4 sides, 2 rows) with 1/4-20 thread

R-T-1512-20 - 2.00 in × 1.50 in × 12.00 in tower (4 sides, 2 rows) with 1/4-20 thread

This tower is used to fixture large workpieces or to hold a workpiece vertically. It has 1/4-20 threaded holes and is recommended for use on CMM and Equator™ gauging systems.

R-T-16-20 - 1.00 in × 1.00 in  ×  6.00 in tower (4 sides, 1 row) with 1/4-2- thread

R-T-16-20 - 1.00 in × 1.00 in × 6.00 in tower (4 sides, 1 row) with 1/4-2- thread

R-T-16-20 - 1.00 in × 1.00 in  ×  6.00 in tower (4 sides, 1 row) with 1/4-2- thread

This tower is used to fixture large workpieces or to hold a workpiece vertically. It has 1/4-20 threaded holes and is recommended for use on CMM and Equator™ gauging systems.

R-T-230-20 - 2.00 in × 2.00 in × 30.00 in tower (4 sides, 2 rows) with 1/4-20 thread

R-T-230-20 - 2.00 in × 2.00 in × 30.00 in tower (4 sides, 2 rows) with 1/4-20 thread

R-T-230-20 - 2.00 in × 2.00 in × 30.00 in tower (4 sides, 2 rows) with 1/4-20 thread

This tower is used to fixture large workpieces or to hold a workpiece vertically. It has 1/4-20 threaded holes and is recommended for use on CMM and Equator™ gauging systems.

R-CTB-25-8 - M8 tension clamp bracket for use with Ø25.6 mm standoffs

R-CTB-25-8 - M8 tension clamp bracket for use with Ø25.6 mm standoffs

R-CTB-25-8 - M8 tension clamp bracket for use with Ø25.6 mm standoffs

This tension clamp bracket attaches to a standoff and holds the tension clamp at an angle.

R-T-1518-20 - 2.00 in × 1.50 in × 18.00 in tower (4 sides, 2 rows) with 1/4-20 thread

R-T-1518-20 - 2.00 in × 1.50 in × 18.00 in tower (4 sides, 2 rows) with 1/4-20 thread

R-T-1518-20 - 2.00 in × 1.50 in × 18.00 in tower (4 sides, 2 rows) with 1/4-20 thread

This tower is used to fixture large workpieces or to hold a workpiece vertically. It has 1/4-20 threaded holes and is recommended for use on CMM and Equator™ gauging systems.

R-T-224-20 - 2.00 in × 2.00 in × 24.00 in tower (4 sides, 2 rows) with 1/4-20 thread

R-T-224-20 - 2.00 in × 2.00 in × 24.00 in tower (4 sides, 2 rows) with 1/4-20 thread

R-T-224-20 - 2.00 in × 2.00 in × 24.00 in tower (4 sides, 2 rows) with 1/4-20 thread

This tower is used to fixture large workpieces or to hold a workpiece vertically. It has 1/4-20 threaded holes and is recommended for use on CMM and Equator™ gauging systems.

UCC MMI-2 introduction

UCC MMI-2 introduction

UCC MMI-2 introduction The UCC MMI-2 controller provides a USB based interface for manual CMMs.

Modes of operation

Modes of operation

Modes of operation Qualification (calibration of the probe) The SP80 and SP80H probes require qualification (calibration) before it is able to give accurate positional data.

Modes of operation

Modes of operation

Modes of operation Qualification (calibration of the probe) The SP80 and SP80H probes require qualification (calibration) before it is able to give accurate positional data.

PICS introduction

PICS introduction

PICS introduction PHC10-3 PLUS and PI 7-3 PHC10-3 PLUS and PI 7-3 with autochange NOTE: The order in which the elements of the system are connected is important The system must have an...

R-T-25300-8 - 25 mm × 25 mm × 300 mm tower (4 sides, 1 row) with M8 thread

R-T-25300-8 - 25 mm × 25 mm × 300 mm tower (4 sides, 1 row) with M8 thread

R-T-25300-8 - 25 mm × 25 mm × 300 mm tower (4 sides, 1 row) with M8 thread

This tower is used to fixture large workpieces or to hold a workpiece vertically. It has M8 threaded holes spaced at 12.5 mm intervals and is recommended for use on CMM and Equator™ gauging systems.

R-T-35300-6 - 35 mm × 35 mm × 300 mm tower (4 sides, 2 rows) with M6 thread

R-T-35300-6 - 35 mm × 35 mm × 300 mm tower (4 sides, 2 rows) with M6 thread

R-T-35300-6 - 35 mm × 35 mm × 300 mm tower (4 sides, 2 rows) with M6 thread

This tower is used to fixture large components or to hold a part vertically. It has M6 threaded holes spaced at 12.5 mm intervals and is recommended for use on CMM and Equator™ gauging systems.

R-T-35300-8 - 35 mm × 35 mm × 300 mm tower (4 sides, 2 row) with M8 thread

R-T-35300-8 - 35 mm × 35 mm × 300 mm tower (4 sides, 2 row) with M8 thread

R-T-35300-8 - 35 mm × 35 mm × 300 mm tower (4 sides, 2 row) with M8 thread

This tower is used to fixture large workpieces or to hold a workpiece vertically. It has M8 threaded holes spaced at 12.5 mm intervals and is recommended for use on CMM and Equator™ gauging systems.

R-T-50600-6 - 50 mm × 50 mm × 600 mm tower (4 sides, 2 row) with M6 thread

R-T-50600-6 - 50 mm × 50 mm × 600 mm tower (4 sides, 2 row) with M6 thread

R-T-50600-6 - 50 mm × 50 mm × 600 mm tower (4 sides, 2 row) with M6 thread

This tower is used to fixture large workpieces or to hold a workpiece vertically. It has M6 threaded holes spaced at 12.5 mm intervals and is recommended for use on CMM and Equator™ gauging systems.

R-T-50600-8 - 50 mm × 50 mm × 600 mm tower (4 sides, 2 rows) with M8 thread

R-T-50600-8 - 50 mm × 50 mm × 600 mm tower (4 sides, 2 rows) with M8 thread

R-T-50600-8 - 50 mm × 50 mm × 600 mm tower (4 sides, 2 rows) with M8 thread

This tower is used to fixture large componentworkpieces or to hold a workpiece vertically.

R-T-50750-6 - 50 mm  × 50 mm × 750 mm tower (4 sides, 2 rows) with M6 thread

R-T-50750-6 - 50 mm × 50 mm × 750 mm tower (4 sides, 2 rows) with M6 thread

R-T-50750-6 - 50 mm  × 50 mm × 750 mm tower (4 sides, 2 rows) with M6 thread

This tower is used to fixture large workpieces or to hold a workpiece vertically. It has M6 threaded holes spaced at 12.5 mm intervals and is recommended for use on CMM and Equator™ gauging systems.

R-T-50750-8 - 50 mm × 50 mm × 750 mm tower (4 sides, 2 rows) with M8 thread

R-T-50750-8 - 50 mm × 50 mm × 750 mm tower (4 sides, 2 rows) with M8 thread

R-T-50750-8 - 50 mm × 50 mm × 750 mm tower (4 sides, 2 rows) with M8 thread

This tower is used to fixture large workpieces or to workpiece a part vertically. It has M8 threaded holes spaced at 12.5 mm intervals and is recommended for use on CMM and Equator™ gauging systems.

R-T-35450-6 - 35 mm × 35 mm × 450 mm tower (4 sides, 2 rows) with M6 thread

R-T-35450-6 - 35 mm × 35 mm × 450 mm tower (4 sides, 2 rows) with M6 thread

R-T-35450-6 - 35 mm × 35 mm × 450 mm tower (4 sides, 2 rows) with M6 thread

This tower is used to fixture large components or to hold a part vertically. It has M6 threaded holes spaced at 12.5 mm intervals and is recommended for use on CMM and Equator™ gauging systems.

RVP installation

RVP installation

RVP installation Fitting VPCP and VMCP to the MRS / MRS2 rack The VPCP and VMCP heated change ports can be fixed to an MRS or MRS2 rack system.

RFP1 fringe  probe for the REVO® system

RFP1 fringe probe for the REVO® system

RFP, the new structure light measurement probe for the REVO 5-axis system, delivers clear advantages for the inspection of freeform surfaces and complex geometry, such as additively manufactured...

Zobrazení 351 - 400 ze 2901