Nalezen výsledek pro CMM

RTP20 system description

RTP20 system description

RTP20 system description RTP20 is an indexable head that uses the CMM's motion for repeatable repositioning.

UCC MMI general wiring standards

UCC MMI general wiring standards

UCC MMI general wiring standards To achieve reliable operation of the UCC MMI and the CMM host computer, the following should be observed: Scale readhead signals, reference marks and error signals...

System signals

System signals

System signals The functions of all PICS signals are described in this section, but it must not be assumed that all interfaces and controllers support every signal.

SPA2-2 references and associated documents

SPA2-2 references and associated documents

SPA2-2 references and associated documents The following Renishaw documents are referred to in this document or may be a source of further relevant information.

PH10 Operating Modes

PH10 Operating Modes

PH10 Operating Modes The PH10 system can operate in one of two modes: • Manual mode • Automatic mode Manual mode In manual mode the optional HCU1 hand control unit is used to control head and...

Connecting SP80 / SP80H using UCC PI 80

Connecting SP80 / SP80H using UCC PI 80

Connecting SP80 / SP80H using UCC PI 80 3-axis CMM with brushed motors 3-axis CMM with DC motors 3- or 4-axis CMM with brushless motors 3- or 4-axis large CMM with motors requiring an analogue...

MODUS™ Planning Suite

MODUS™ Planning Suite

MODUS™ Planning Suite makes complex programming simple with offline tools and simulations to create code representing machine measurements and deliver a collision free path.

MMclient

MMclient

MMclient MMclient allows existing MeasureMax* programs to be run on a CMM utilising Renishaw's UCC controller system.

MCG tools setup worksheet

MCG tools setup worksheet

MCG tools setup worksheet MCG tools setup home page The setup page provides the one portal required to enter all the parameters required to prepare MCG tools for a CMM verification.

Connectivity

Connectivity

Connectivity 3- or 4-axis large CMM with motors requiring an analogue servo power amplifier The UCC PI 80 has different configuration layouts to provide an interface to CMM systems with three,...

UCC1 legacy controller

UCC1 legacy controller

UCC1 legacy controller The UCC1 has a range of compatible additional card options.

MCU references and associated documents

MCU references and associated documents

MCU references and associated documents It is recommended that the following documentation be referred to when installing an MCU.

REVO 5-axis measurement system

REVO 5-axis measurement system

Revolutionary head and probe system designed to maximise CMM throughput whilst maintaining high accuracy.

Changers promotion

Changers promotion

Free Renishaw changer racks and probe modules offer from participating CMM suppliers. Conditions apply.

UCC BI references and associated documents

UCC BI references and associated documents

UCC BI references and associated documents It is recommended that the following documentation is referenced when installing the UCC BI: Renishaw documents External documents National and...

PH20 5-axis touch-trigger system

PH20 5-axis touch-trigger system

Renishaw’s new PH20 5-axis head for touch-trigger inspection on CMMs gives up to three-fold increase in throughput on a wide range of co-ordinate measuring machines (CMMs).

System operation

System operation

System operation Speed override - MCU W If the joystick is taken out of range while the CMM is moving in automatic mode the loss of the radio link will not stop the CMM, but if the...

Machine builder case studies

Machine builder case studies

Renishaw case studies for the machine builder industry.

PL27 and PL29 manual probe head cables

PL27 and PL29 manual probe head cables

These coiled cables have 90° moulded 5-pin DIN plugs at each end and electrically connect Renishaw manual probe heads to the CMM quill.

MCU5 legacy hand controller

MCU5 legacy hand controller

Compatible with the range of Renishaw CMM controllers and incorporates all the functionality of the HCU1 hand controller for motorised head

R-CTB-19-6 - M6 tension clamp bracket for use with Ø19.4 mm standoffs

R-CTB-19-6 - M6 tension clamp bracket for use with Ø19.4 mm standoffs

R-CTB-19-6 - M6 tension clamp bracket for use with Ø19.4 mm standoffs

This tension clamp bracket attaches to a standoff and holds the tension clamp at an angle.

R-CTB-25-6 - M6 tension clamp bracket for use with Ø25.6 mm standoffs

R-CTB-25-6 - M6 tension clamp bracket for use with Ø25.6 mm standoffs

R-CTB-25-6 - M6 tension clamp bracket for use with Ø25.6 mm standoffs

This tension clamp bracket attaches to a standoff and holds the tension clamp at an angle.

PHC10-3 PLUS system interconnection diagrams

PHC10-3 PLUS system interconnection diagrams

PHC10-3 PLUS system interconnection diagrams PH10 PLUS system with standard two wire touch-trigger probes With internal PI 200-3 and autochange PH10 PLUS system with standard two wire touch-t...

R-T-25150-6 - 25 mm × 25 mm × 150 mm tower (4 sides, 1 row) with M6 thread

R-T-25150-6 - 25 mm × 25 mm × 150 mm tower (4 sides, 1 row) with M6 thread

R-T-25150-6 - 25 mm × 25 mm × 150 mm tower (4 sides, 1 row) with M6 thread

This tower is used to fixture large workpieces or to hold a workpiece vertically. It has M6 threaded holes spaced at 12.5 mm intervals and is recommended for use on CMM and Equator™ gauging systems.

Retrofit cabinet introduction

Retrofit cabinet introduction

Retrofit cabinet introduction Renishaw's controller cabinet is a standard 19 inch rack mounting unit that is used for storing Renishaw's range of controllers, servo power amplifiers and interfaces.

PI 7-3 maintenance

PI 7-3 maintenance

PI 7-3 maintenance Check the security of mounting screws and electrical connectors Remove dust from the external surfaces with a proprietary cleaning cloth There are no user serviceable parts withi...

SPA2-2 installation guide

SPA2-2 installation guide

The SPA2-2 is a digital servo power amplifier solution designed specifically for use with the Renishaw brushless motor interfaces (e.g. UCC BI), and the now obsolete UCC2 or UCClite-2 controllers.

R-T-25300-6 - 25 mm  × 25 mm × 300 mm tower (4 sides, 1 row) with M6 thread

R-T-25300-6 - 25 mm × 25 mm × 300 mm tower (4 sides, 1 row) with M6 thread

R-T-25300-6 - 25 mm  × 25 mm × 300 mm tower (4 sides, 1 row) with M6 thread

This tower is used to fixture large workpieces or to hold a workpiece vertically.

A-1034-0351 - M8 datum ball fixing stud

A-1034-0351 - M8 datum ball fixing stud

A-1034-0351 - M8 datum ball fixing stud

A-1034-0351 M8 datum ball fixing stud M8 threaded inserts used to mount Renishaw datum sphere kits to the CMM bed.

A-1034-0350 - M10 datum ball fixing stud

A-1034-0350 - M10 datum ball fixing stud

A-1034-0350 - M10 datum ball fixing stud

A-1034-0350 M10 datum ball fixing stud M10 threaded inserts used to mount Renishaw datum sphere kits to the CMM bed.

A-1034-0352 - M6 datum ball fixing stud

A-1034-0352 - M6 datum ball fixing stud

A-1034-0352 - M6 datum ball fixing stud

A-1034-0352 M6 datum ball fixing stud M6 threaded inserts used to mount Renishaw datum sphere kits to the CMM bed.

Motorised head and autochange rack controllers

Motorised head and autochange rack controllers

A range of control systems to interface between Renishaw's motorised heads and autochange racks and your CMM.

PH10 Overload error

PH10 Overload error

The OVERLOAD ERROR and STOP LEDs are lit on the controller. The head has been overloaded while locked.

PH10 Machine Checking Gauge

PH10 Machine Checking Gauge

PH10 Machine Checking Gauge The Renishaw machine checking gauge enables rapid and effective interim checking of CMM performance as recommended by many standards for CMM volumetric performance assessment.

3-2-1 fixturing principle - How to improve the inspection throughput, reproducibility and accuracy

3-2-1 fixturing principle - How to improve the inspection throughput, reproducibility and accuracy

Applying the 3-2-1 fixturing principle can improve the throughput, reproducibility and accuracy of your inspection process.

Attaching the KM80 quill adaptor plate

Attaching the KM80 quill adaptor plate

Attaching the KM80 quill adaptor plate Mounting the SP80 and SP80H on the CMM via the KM80 is the recommended method due to its inherent stiffness, as well as the reduced overall Z length when...

System connections

System connections

System connections The REVO system components are connected as shown below: NOTE: Please note that the SPA2-2 needs to be a suitable configuration for the REVO system.

R-CT-100P-83-6 - 92.0 mm tension clamp with 82.8 mm post and adjustable plunger tip and M6 thread

R-CT-100P-83-6 - 92.0 mm tension clamp with 82.8 mm post and adjustable plunger tip and M6 thread

R-CT-100P-83-6 - 92.0 mm tension clamp with 82.8 mm post and adjustable plunger tip and M6 thread

This tension clamp is used for the quick and easy clamping of workpiecess onto CMM and Equator™ systems.

A-1371-0163 - MCR20 rack kit for automatic stylus changing with TP20 - rack only

A-1371-0163 - MCR20 rack kit for automatic stylus changing with TP20 - rack only

A-1371-0163 - MCR20 rack kit for automatic stylus changing with TP20 - rack only

The MCR20 module changing rack is designed to securely store up to six TP20 probe modules for automatic changing, and to protect them from airborne contaminants.

UCC MMI-2 installation guide

UCC MMI-2 installation guide

The UCC MMI-2 controller provides a USB based interface for manual CMMs.

Renishaw changers

Renishaw changers

Free Renishaw changer racks and probe modules with every new PH10 head purchased, from participating CMM suppliers

MRS modular rack system

MRS modular rack system

Renishaw's modular rack system (MRS) allows customisation of probe and stylus changing racks to optimise CMM functionality

Safety data sheets

Safety data sheets

Renishaw and third party safety data sheets for CMM products.

Accessories - China RoHS

Accessories - China RoHS

Accessories - China RoHS Browse documents China RoHS - PAA China RoHS - PEM China RoHS - Retrofit PCBs China RoHS - PHA China RoHS - TP20 bush China RoHS - RPM01 China RoHS - Autojoints China Ro...

Systems - China RoHS

Systems - China RoHS

China RoHS tabulations for the Renishaw CMM product line - systems

Heads - China RoHS

Heads - China RoHS

Heads - China RoHS Browse documents China RoHS - PH20 China RoHS - MH8 China RoHS - MH20 China RoHS - MH20i China RoHS - REVO-2 China RoHS - PH6M China RoHS - RTP20 China RoHS - PHS-2 China RoHS...

Controllers - China RoHS

Controllers - China RoHS

Controllers - China RoHS Browse documents China RoHS - ACC2-3 China RoHS - MCU W China RoHS - MCU W-2 China RoHS - MCU5 China RoHS - MCU5-2 China RoHS - MCUlite-2 China RoHS - UCC AI China RoHS ...

Probes - China RoHS

Probes - China RoHS

Probes - China RoHS Browse documents China RoHS - SFP2 - TFP tip find probe China RoHS - SFP2 - C-axis China RoHS - SFP2 - SFH holder range China RoHS - SFP2 - SFM module range China RoHS - RSP3...

Interfaces - China RoHS

Interfaces - China RoHS

Interfaces - China RoHS Browse documents China RoHS - PI 7-3 China RoHS - PI 200-3 China RoHS - IS1-2 China RoHS - IU80

AU declarations of conformity

AU declarations of conformity

AU declarations of conformity for the Renishaw CMM product line

Zobrazení 201 - 250 ze 2881