MIH manual indexing probe head
MIH manual indexing probe head NOTE: Dimensions in mm (in).
Renishaw probing reduces scrap and saves time at precision subcontractor
The advanced manufacturing division of Intoco (Independent Tool Consultants Ltd) a Gloucestershire, UK, based company, is a showcase for precision subcontract engineering.
MH20i
MH20i The A-axis rotates through ±180° in the X-Y plane.
ZH - 安全须知
ZH - 安全须知 如果设备使用方式与制造商要求的方式不符,则可能会损害设备的安全性能。 警告: SPA3 必须布置地线。整台机器的地线布置由 OEM 或安装服务商负责。 警告: SPA3 不能直接由主电源供电。 必须使用符合 BS EN 60950-1:2006+A2:2013(或当前版本)标准的单个容错电源装置,并连接到带有保护性接地导体的电源上。 机器安全须知 警告: ...
Faster shop-floor inspection with AGILITY and REVO® 5-axis multi-sensor CMM system
This application note describes how the Renishaw AGILITY and REVO 5-axis multi-sensor system, is utilised for shop floor use and addresses the inspection challenges for automotive parts.
FCR25-L3 three port standalone change rack
The FRC25-L3 is a triple port standalone rack, based on the FCR25.
Scale inputs
Scale inputs Provides RS422 compatible scale inputs for each of the machine axes through the 15 W HDD connectors.
BG - Безопасност
BG - Безопасност ВНИМАНИЕ: Преди разопаковане и монтиране на системата REVO, потребителят трябва внимателно да прочете инструкциите по безопасност по-долу и да гарантира, че те ще се спазват през...
SCR600 pick up / put down routine
SCR600 pick up / put down routine Picking up routine for SCR600 port (N) Operation X-axis Y-axis Z-axis Clearance position X(s) Y(n) +8 mm (+0.
IT - Sicurezza
IT - Sicurezza ATTENZIONE: Prima di estrarre il sistema REVO dall'imballo e iniziare l'installazione, leggere attentamente le istruzioni riportate di seguito e controllare che vengano sempre...
EL - Ασφάλεια
EL - Ασφάλεια Εκπομπές φωτοδιόδων LED του RSP3 Η σειρά αισθητήρων σάρωσης RSP3 περιέχει ενσωματωμένες πηγές LED υψηλής ισχύος και δεν πρέπει να χρησιμοποιείται στην περίπτωση σοβαρής βλάβης σε, ή...
Abbreviations
Abbreviations ACC2-3 Auotchange controller ACR1 Autochange rack CCA Change cycle aborted (error condition) CMM Coordinate measuring machine CNA Command not accepted (error report) CR Carriage ...
PH10 Compatible Probes
PH10 Compatible Probes M8 touch-trigger probes This range of probes utilises the M8 bush for mounting to the head.
SFP1 system description
SFP1 system description SFP1 is a dedicated lightweight surface finish measurement probe for use with Renishaw's 5-axis REVO system.
PHC10-3 PLUS introduction
PHC10-3 PLUS introduction The guide gives information on physical installation, system connections, communications and interface settings, as well as assistance in fault-finding during the...
OTP6M legacy probe
OTP6M legacy probe Z-axis repeatability (2σ) 2 μm* 1D Measurement accuracy (band width) ±25 μm** Stand-off distance 36 mm Inclined angles 60°* Operating range (nominal value depending on target...
SV - Säkerhetsföreskrifter
SV - Säkerhetsföreskrifter Om utrustningen används på ett sätt som inte tillverkaren har avsett kanske skyddet fungerar sämre.
SV - Säkerhetsföreskrifter
SV - Säkerhetsföreskrifter Infrarött ljus LED-PRODUKT KLASS 1 Varningar Det finns risk för klämning mellan rörliga delar och mellan rörliga och stillastående delar.
CS - Bezpečnost
CS - Bezpečnost UPOZORNĚNÍ: Vněkterých součástech systému PH20 apřidružených produktů jsou použity permanentní magnety.
DA - Sikkerhed
DA - Sikkerhed Advarsler Pas på uventede bevægelser.
ZH - 安全须知
ZH - 安全须知 如果产品上显示此符号,用户必须参见“安装指南”,了解相关信息和安全建议。 警告: 可以通过断开外部电源装置的交流电源接头来切断 SPA3-2 的电源。如果需要任何形式的额外绝缘隔离措施,必须由设备制造商或产品安装人员指定并安装。隔离器必须位于 CMM 操作人员易于操作的位置,并且符合 BS EN 61010-1:2010(或当前版本)和设备安装所在国适用的国家...
AEREO - EMA’s multivanes
Europea Microfusioni Aerospaziali (EMA), is part of the Rolls-Royce Group, a world leader in the manufacturing of propulsion systems for civil and military aircraft, ships, submarines and turbines...
PH20 inspecting AEREO - EMA’s multivanes
Europea Microfusioni Aerospaziali (EMA), is part of the Rolls-Royce Group, a world leader in the manufacturing of propulsion systems for civil and military aircraft, ships, submarines and turbines...
Custom M12 Metrology table with black oxide finish
Custom M12 Metrology table with black oxide finish
Vittorio Caggiano, Marco Iannuzzi and Maurizio Rullo in EMA’s metrology room
Europea Microfusioni Aerospaziali (EMA), is part of the Rolls-Royce Group, a world leader in the manufacturing of propulsion systems for civil and military aircraft, ships, submarines and turbines...
REVO RCP TC DC link cable
DC link cable for daisy chaining RCP TC change ports. No more than four RCP TC units can be pored from one PSU. No more than one PSU should be connected to a daisy chain of ports.
EMA’s metrology room
Europea Microfusioni Aerospaziali (EMA), is part of the Rolls-Royce Group, a world leader in the manufacturing of propulsion systems for civil and military aircraft, ships, submarines and turbines...
UCC AI
CAD models for the UCC AI controller
EM2 standard force module (75 mm extension)
The TP20 is a compact module changing touch-trigger probe.
Maurizio Rullo using Equator
Europea Microfusioni Aerospaziali (EMA), is part of the Rolls-Royce Group, a world leader in the manufacturing of propulsion systems for civil and military aircraft, ships, submarines and turbines...
UCC BI
CAD models for the UCC BI controller
Machine I/O (44W HDD socket)
Machine I/O (44W HDD socket) The machine I/O socket is used to provide connections for the CMM input / output.
ZH-TW - RUP1 安全手冊
ZH-TW - RUP1 安全手冊 RUP1 警告 謹防意外移動。使用者應該與測頭座和測針的整個操作運動範圍保持一段安全距離,機器供應商應確實讓使用者瞭解該系統的整個操作運動範圍。 在所有涉及使用工具機或三次元量床的應用中,建議要有眼睛保護措施。 機器供應商有責任確保使用者瞭解操作機器所存在的任何危險,包括 Renishaw 產品說明書中提及之情況,並保證提供充分的安全防護罩和安全聯鎖裝置。...
UCC MMI-2 troubleshooting
UCC MMI-2 troubleshooting Probe seated Error Description Fault Solution Constant red error LED Power fault/ FPGA reset In the event of this fault, check the power supply or else, please return...
Machine repair specialist invests in Renishaw multi-axis calibrators to expand its services
To become the go-to calibration service provider to its customers, KES Machine LLC has expanded its relationship with global engineering technologies company, Renishaw.
UCC BI troubleshooting
UCC BI troubleshooting Description LED on, displaying green, amber or red Red flash Green flash LED off NOTE: ** A slow flash synchronised with the controller's slow flashing status...
Upgrades and free products
Upgrades and free products UCC retrofit Renishaw has formed a technical partnership with some of the industry's leading software companies and retrofitters to provide powerful CMM retrofit...
UCC S3
CAD models for the UCC S3 controller
50% faster turbine blade inspection
Europea Microfusioni Aerospaziali (EMA), is part of the Rolls-Royce Group, a world leader in the manufacturing of propulsion systems for civil and military aircraft, ships, submarines and turbines...
EM1 standard force module
EM1 standard force module, part of the EM1 and EM2 standard force module kit.
50% faster turbine blade inspection
Europea Microfusioni Aerospaziali (EMA), is part of the Rolls-Royce Group, a world leader in the manufacturing of propulsion systems for civil and military aircraft, ships, submarines and turbines...
Renscan5™ and REVO® - Technology and applications
Renscan5™ and REVO™, “the most revolutionary metrology product since the invention of the touch trigger probe”
Custom fixture using Spring loaded clamps to hold four parts in two orientations
Custom fixture using Spring loaded clamps to hold four parts in two orientations
Manual probe heads product overview
Manual probe heads product overview Renishaw manual probe heads detailed in this user's guide are designed to suit any CMM and this specifically covers: PH1 PH6 PH6M Each is designed for a specific...
SK - Bezpečnosť