Filtrovat podle
Nalezen výsledek pro CMM
CMM Fixturing finished assembly
For use on the website.
Background technologies button
CMM background technologies
MCG machine checking gauge
calibration,cmm,mcg
System installation
System installation PH20 initialisation and commissioning sequence The PH20 system should be commissioned using Renishaw's UCCassist-2 software.
Renishaw enters the CMM retrofit market
Renishaw assembles the technol
M8 CMM clamping kit B with 600 mm x 600 mm aluminium plate
This M8 CMM clamping kit can be used to hold brass, titanium, aluminium, plastic, ferrous and non-ferrous parts.
M8 CMM clamping kit B with 300 mm x 300 mm aluminium plate
This M8 CMM clamping kit can be used to hold brass, titanium, aluminium, plastic, ferrous and non-ferrous parts.
M6 CMM clamping kit B with 300 mm x 300 mm aluminium plate
This M6 CMM clamping kit can be used to hold brass, titanium, aluminium, plastic, ferrous and non-ferrous parts.
M6 CMM clamping kit B with 450 mm x 450 mm aluminium plate
This M6 CMM clamping kit can be used to hold brass, titanium, aluminium, plastic, ferrous and non-ferrous parts.
M8 CMM clamping kit A with 450 mm x 450 mm aluminium plate
This M8 CMM clamping kit can be used to hold brass, titanium, aluminium, plastic, ferrous and non-ferrous parts.
M8 CMM clamping kit B with 450 mm x 450 mm aluminium plate
This M8 CMM clamping kit can be used to hold, brass, titanium, aluminium, plastic, ferrous and non-ferrous parts.
M8 CMM clamping kit A with 300 mm x 300 mm aluminium plate
This M8 CMM clamping kit can be used to hold brass, titanium, aluminium, plastic, ferrous and non-ferrous parts.
M6 CMM clamping kit B with 600 mm x 600 mm aluminium plate
This M6 CMM clamping kit can be used to hold brass, titanium, aluminium, plastic, ferrous and non-ferrous parts.
M6 CMM clamping kit A with 600 mm x 600 mm aluminium plate
This M6 CMM clamping kit can be used to hold brass, titanium, aluminium, plastic, ferrous and non-ferrous parts.
M8 CMM clamping kit A with 600 mm x 600 mm aluminium plate
This M8 CMM clamping kit can be used to hold brass, titanium, aluminium, plastic, ferrous and non-ferrous parts.
M6 CMM clamping kit A with 450 mm x 450 mm aluminium plate
This M6 CMM clamping kit can be used to hold brass, titanium, aluminium, plastic, ferrous and non-ferrous parts.
M6 CMM clamping kit A with 300 mm x 300 mm aluminium plate
This M6 CMM clamping kit can be used to hold brass, titanium, aluminium, plastic, ferrous and non-ferrous parts.
ACR3 sensor changing
The ACR3 enables up to 8 different sensors to be used on one measuring machine via a fast and highly repeatable changing system.
RSP3-6 scanning probe - Combining long extensions with REVO 5-axis movements
The RSP3-6 combines long extensions with REVO 5-axis movements for better part access.
ACR2 introduction
ACR2 introduction System features Modular construction Ports can be positioned in pairs anywhere on the machine.
PH10M-iQ PLUS system description
PH10M-iQ PLUS system description PH10M-iQ PLUS body dimensions Positioning Dimensions from quill face ** The inferred calibration procedure is different depending on the chosen orientation...
ACR2 autochange rack
ACR2 autochange rack Six-port ACR2 installation: The ACR2 autochange rack is an arm-changing system for the PHS1 servo positioning head.
REVO-2 calibration
REVO-2 calibration System calibration Probe type A (in mm) - Ø30 sphere A (in mm) - Ø45 sphere RSP2 with RSH175 420* 435* RSP2 with RSH250 570* 585* RSP2 with RSH350 770* 785* RSP2 with...
ACR2 autochange rack
ACR2 autochange rack Modular construction Ports can be positioned in pairs anywhere on the machine.
GA - Sábháilteacht
GA - Sábháilteacht RABHADH: Ba chóir don úsáideoir na treoracha sábháilteachta thíos a léamh go cúramach sula ndéantar an córas PH20 a dhíphacáil agus a shuiteáil, agus a chinntiú go leanann gach...
Installation of the UCC2 and UCC2-2 components
Installation of the UCC2 and UCC2-2 components Installation of daughtercards Connecting the UCC2 mains supply This installation must be undertaken by suitably experienced and / or qualified personnel.
ET - RUP1 ohutus
ET - RUP1 ohutus RUP1 hoiatused Olge ettevaatlik ootamatute liikumiste suhtes.
RTP1 temperature probe for the REVO® system
The RTP1 probe adds automated part temperature measurement as part of the REVO 5-axis multi-sensor measuring system.
MCU maintenance
MCU maintenance NOTE: The external surfaces of all system components can be cleaned with a water damped cloth but all parts should be kept dry.
Head installation
Head installation The PHS1 probe head mounts onto the CMM quill via a kinematic mounting plate.
RTP1 probe change system
RTP1 probe change system NOTE: Dimensions are shown in mm (in).
White papers - Styli
White papers - Styli Browse documents Effects of continuous scanning on stylus balls The importance of stylus cleaning Wear comparison testing between Renishaw OPTiMUM™ diamond styli and the...
Isolation
Isolation The power switch is used to switch off the power to the internal equipment.
FCR25 flexible change rack system
FCR25 flexible change rack system FCR25 is a flexible change rack system that can be either mounted to an MRS rail or supplied with a standalone leg which can be fixed to the bed of the CMM.
MCU maintenance
MCU maintenance The MCUlite-2 and MCU5-2 have no user serviceable parts.
System interconnection diagrams
System interconnection diagrams PH10M-iQ PLUS and PHC10-3 PLUS Key Description 1 PH10M-iQ PLUS head 2 PHC10-3 PLUS 3 HCU2 4 Head cable 5 Communication connection to CMM controller (RS232 or USB) ...
Head installation
Head installation Kinematic joint locking mechanism (shown locked): The PHS1 probe head mounts onto the CMM quill via a kinematic mounting plate.
Datum sphere
A range of spheres for probe qualification, mounted on a stem that can be adjusted for a wide range of qualification angles.
FI - Turvallisuus
FI - Turvallisuus Liikkuvien osien ja staattisten osien välillä on litistymisvaara.
Earth bonding scheme
Earth bonding scheme CAUTION: The capability to use the UCC BI in a dual SPA system or a system using absolute scales is not yet available, please contact CMM support for further information.
MCU maintenance
MCU maintenance NOTE: The external surfaces of all system components can be cleaned with a water damped cloth but all parts should be kept dry.
AGILITY S 796 R CMM and REVO-2 with RSP2
AGILITY S 796 R CMM with the REVO 5-axis multi-sensor system's RSP2 scanning probe and MCU joystick in situ.