Results found for tp6

<<123>>
Manuals and installation guide downloads

Manuals and installation guide downloads

Manuals and installation guide downloads Legacy products Manuals and installation guides for superseded or obsolete products.

Kinematic_location

Kinematic_location

Installation manuals - CMM products

Installation manuals - CMM products

Installation manuals - CMM products Browse documents Autochange system PHC10-3 PLUS SPA2-2 PI 200-3 SP80 and SP80H PH20 UCC T3 PLUS and UCC S3 CMM controller IS1-2 PHS-2 SP25M MCUlite-2, MCU5-2...

PH10 PLUS system description

PH10 PLUS system description

PH10 PLUS system description CAUTION: Please ensure that the head is mounted as rigidly as possible in the CMM's quill.

PHC10-3 Probe Head Controller

PHC10-3 Probe Head Controller

PHC10-3 Probe Head Controller Powering the PHC10-3 The PH10-3 head controller is to be used with the provided PSU - (Emerson DP4024N3M AC power adptor).

UCC T3-2 introduction

UCC T3-2 introduction

UCC T3-2 introduction The UCC T3-2 is the latest generation Renishaw CMM controller product range.

MCG systems

MCG systems

MCG systems The probe's stylus slots into the end of what is, in effect, a reference 'ball' bar.

UCC MMI-2 universal CMM controller

UCC MMI-2 universal CMM controller

UCC MMI-2 universal CMM controller Interfaces to the Renishaw digital range of scale readheads, or electrically compatible OEM versions, and to TP20 or similar touch-trigger probes Controls the...

TP200 touch-trigger probe components

TP200 touch-trigger probe components

TP200 touch-trigger probe components TP200 probe body Incorporates micro strain gauge transducers, delivering excellent repeatability and accurate 3D form measurement even with long styli Sensor...

Legacy products

Legacy products

Legacy products For information regarding current products please refer to the 'Installation and user's guide downloads ' page.

TP200 touch-trigger probe system

TP200 touch-trigger probe system

TP200 touch-trigger probe system Features and benefits Excellent repeatability and precision 3D form measurement Rapid exchange between stylus configurations without the need to re-calibrate...

Upgrades and free products

Upgrades and free products

Upgrades and free products UCC retrofit Renishaw has formed a technical partnership with some of the industry's leading software companies and retrofitters to provide powerful CMM retrofit...

Part number summary

Part number summary

Part number summary Probes Description Part number TP200 probe body A-1207-0020 TP200B probe body A-1207-0056 Probe kits Description Part number TP200 probe kit 1 (including standard force...

MH8 manual indexing probe head

MH8 manual indexing probe head

MH8 manual indexing probe head Part number MH8 probe head only A-1332-0002 MH8 probe head kit, includes required shank (see below for complete part number) A-1332-**** Part Number Price...

TP200 product description

TP200 product description

TP200 product description Probe body The TP200 probe body houses the strain sensing structure and electronic processing circuitry.

ACR3 autochange rack

ACR3 autochange rack

ACR3 autochange rack 4 port ACR3 system dimensions 8 port ACR3 system dimensions Dimensions Total swept volume along the MRS during a change cycle is: 1 × ACR3 275 mm (10.

Gear inspection is 30 times faster with form measurement

Gear inspection is 30 times faster with form measurement

Meltham Mills Engineering (MME) now takes only eight minutes to inspect every critical feature on a typical gear component, compared to four hours previously – 30 times faster.

PH10 legacy probe heads

PH10 legacy probe heads

PH10 legacy probe heads Each of the heads in the PH10 motorised probe head range is a general purpose, versatile unit designed specifically for use on direct computer controlled (DCC) coordinate...

PI 200-3 product description

PI 200-3 product description

PI 200-3 product description System overview A small deflection of the stylus tip produces a force which is applied via the stylus module and kinematic coupling to the strain sensing...

UCC T3 PLUS and UCC S3 introduction

UCC T3 PLUS and UCC S3 introduction

UCC T3 PLUS and UCC S3 introduction The UCC T3 PLUS / UCC S3 are the latest generation Renishaw CMM controller products.

Manual probe heads - M8 or autojoint - family tree

Manual probe heads - M8 or autojoint - family tree

Product description and pin outs

Product description and pin outs

Product description and pin outs Configuration switches Technical description The PI 7-3 automatically recognises the probe type, determines the probe status, which is either triggered or...

Technical data

Technical data

Technical data MCR20 Measuring performance Technical specifications TP20 NOTE: The following data is derived from high accuracy test rig measurements and may not represent the performance...

System installation

System installation

System installation This section describes the connections and cables used on the PHS1 servo positioning head system.

Manual probe heads description and operation

Manual probe heads description and operation

Manual probe heads description and operation Renishaw manual probe heads provide the mechanical and electrical connections required when using the majority of Renishaw touch-trigger probes...

TP20 probe modules

TP20 probe modules

TP20 probe modules The Renishaw TP20 probe modules incorporate a kinematic coupling, which ensures highly repeatable stylus tip positioning.

IS1-2 installation

IS1-2 installation

IS1-2 installation Changing the programming modules default configuration Key Description 1 - 4 Output channel selected indicators 5 Power on indicator Rear panel of IS1-2 Key...

A-1039-0041 - TP6A tool kit

A-1039-0041 - TP6A tool kit

A-1039-0041 - TP6A tool kit

Tool kit for installing and maintaining PH6A.

Installation procedure

Installation procedure

Installation procedure WARNING: Ensure the PI 200-3 is disconnected from the power adapter during installation.

Product Environmental Compliance

Product Environmental Compliance

Renishaw plc is a supplier of articles and substances. Please see Renishaw's REACH policy statement.

P-GA01-0001 - Trigger force gauge

P-GA01-0001 - Trigger force gauge

P-GA01-0001 - Trigger force gauge

The trigger force gauge is used when requalifying the probe configuration and checking the measurement performance of the probe after any adjustment has been made to the trigger force.

Connectors and signals

Connectors and signals

Connectors and signals CAUTION: The connection of the cabling should be such that the CMM's movements, as reported by the UCC2, are of the correct polarity i.

TP6A

TP6A

TP6A

TP6A system configuration

TP6A system configuration

TP6A system configuration

MIH

MIH

MIH The MIH features an autojoint probe mount for fast, repeatable probe changing.

ACR1

ACR1

ACR1 Mounted within the CMMs working envelope, the ACR1 autochanger enables fast, automatic probe exchange without the need for requalification.

MIH introduction

MIH introduction

MIH introduction Renishaw's MIH is a compact manual indexable probe head which offers the flexibility and time saving normally associated with direct computer controlled (DCC) machines and motorised...

MIH manual indexing probe head

MIH manual indexing probe head

MIH manual indexing probe head Dimensions A manually indexable head with 720 locking positions and integral LCD display Part Number Price (€) Extended Warranty (€) MIH manual indexing head...

Probes - UK declarations of conformity

Probes - UK declarations of conformity

Probes - UK declarations of conformity stylus holders SFH UKD2021-00726 touch-trigger TP20 UKD2021-00770 touch-trigger TP200 UKD2021-00769 probe SFP2 UKD2021-00749-02 touch-trigger TP2 UKD2021-0...

PH6M specification

PH6M specification

PH6M specification Repeatability 1 µm (2σ) at stylus tip 50 mm (1.

Installing a manual probe head

Installing a manual probe head

Installing a manual probe head Fitting an M8-threaded CMM touch-trigger probe to a manual probe head Fit an M8-threaded non-autojointed CMM touch-trigger probe to a manual probe head as...

MIH-S legacy head

MIH-S legacy head

MIH-S legacy head This enables the CMM computer to: verify that the MIH-S has been moved to the correct position and locked in place identify the position which the MIH-S has been locked into...

PH10M-iQ PLUS system description

PH10M-iQ PLUS system description

PH10M-iQ PLUS system description Product Description PH10M-iQ PLUS A shank-mounted head with multiwired probe capability, a Renishaw autojoint and inferred qualification HCU2 A hand control...

TP6A touch-trigger probe

TP6A touch-trigger probe

China RoHS - TP6H

China RoHS - TP6H

TP6A dimensions

TP6A dimensions

China RoHS - TP6A

China RoHS - TP6A

Trigger force gauge

Trigger force gauge

The trigger force gauge is used when requalifying the probe configuration and checking the measurement performance of the probe after any adjustment has been made to the trigger force.

TP6A

TP6A

<<123>>
Showing 101 - 149 of 149